Florida Water Star
Page Top Rounded Corners

Florida Water StarSM Technical Manual

Irrigation system criteria

Distribution (application) uniformity

Pipe sizing

Background
Pipe sizing specification on irrigation design drawing

Pipe sizing specification on irrigation design drawing.

A maximum 5 feet per second (ft/s) water flow velocity is the industry standard for maintaining irrigation system integrity. Velocities above this rate can damage components, essential to the irrigation system’s operation.

Potentially damaging velocities correlate with smaller pipe diameters and, to a lesser extent, specific pipe material properties. The likely result of an incorrect pipe size is water hammer, which occurs when a wave of energy travels back and forth through the water in the pipe causing stress to the pipe, joint and adhesive holding the system together.

The graphic at right is taken from an irrigation design and depicts pipe-sizing specifications that would be reviewed to determine correct pipe sizing during a Florida Water StarSM evaluation.

Requirements and certification

Pipes are sized to prevent velocities greater than 5 feet per second (ft/s).

Silver

Gold

Commercial/Institutional

Required

Required

Required

A friction loss chart is shown for Class 160 polyvinyl chloride (PVC) pipe. The shaded areas represent velocities over 5 ft/s, requiring a larger pipe to be used. Sizing tables are available in most irrigation system manufacturers’ catalogs.

Designers must size pipes according to a recognized pipe sizing/friction loss chart and clearly specify these pipe sizes on the irrigation system design. Installers must install pipes exactly as specified by design.

Friction loss chart for class 160 IPS plastic pipe (Courtesy of the Irrigation Association)

Friction loss chart for class 160 IPS plastic pipe (Courtesy of the Irrigation Association).

St. Johns River Water Management District
4049 Reid Street, Palatka, FL 32177
800-725-5922