Indoor criteria

Fixtures

The plumbing section of the Florida Building Code establishes the maximum flow rate for indoor plumbing fixtures. Most of the maximum flow rates set for Florida code were established by the Energy Policy Act (EPAct) of 1992.

Maximum Flow Rates and Consumption for
Plumbing Fixtures and Fixture Fittings

Plumbing Fixture or Fixture Fitting

Maximum Flow Rate or Quantityb

Lavatory faucet, private

2.2 gpm at 60 psi

Lavatory faucet, public (metering)

0.25 gallon per metering cycle

Lavatory faucet, public
(other than metering)

0.5 gpm at 60 psi

Showerheada

2.5 gpm at 80 psi

Sink faucet

2.2 gpm at 60 psi

Urinal

1.0 gallon per flushing cycle

Toilet

1.6 gallons per flushing cycle

a. A hand-held shower spray is a showerhead.

b. Consumption tolerances shall be determined from referenced standards.

Source: 2007 Florida Building Code – Plumbing
gpm: gallons per minute
psi: pounds per square inch

USEPA WaterSense Program logo

The U.S. Environmental Protection Agency (EPA) WaterSense® program provides a majority of the fixture standards that are required for Florida Water StarSM. Launched in 2006, WaterSense® is an EPA-sponsored partnership program that seeks to protect the future of our nation’s water supply by promoting water efficiency and enhancing the market for water-efficient products, programs and practices.